conductivity measuring transducer
properties:
|
application area:
|
|
GLMU
200 MP
|
![]()
|
| 2 pole meas. cell incl. |
specifications: |
|
measuring ranges: (free selectable by user!) |
conductivity: | 0.0 to 200.0 µS/cm, 0 to
2,000 µS/cm, 0.00 to 20.00 mS/cm, 0.0 to 200.0 mS/cm |
||
| specific resistance: | 5.0 to 100.0 kΩ*cm, 0.50 to 10.00 kΩ*cm,
50 to 1,000 Ω*cm, 5.0 to 100.0 Ω*cm |
|||
| TDS: | 0.0 to 200.0 mg/, 0 to 2,000 mg/l | |||
| salinity: | 0.0 to 70.0 | |||
| temperature meas.: | -5.0°C to +140.0°C (transducer) and 0.0°C to +80.0°C (meas. cell) | |||
| measuring cell: |
|
|||
|
accuracy:
(at nominal temperature = +25°C) |
conductivity: | +0.5 % of meas. value +0.3 % FS | ||
| temperature: | +0.2°C +1 digit | |||
| meas. cell connection: | 7-pole diode connector | |||
| cell constant: | K = 0.30 to 1.20, freey adjustable | |||
|
temperature compensation: (selectable by user) |
off: | no compensation | ||
| Lin: | linear compensation (from 0.3 to 3.0 %/K) | |||
| nLF: | non-linear-function of natural water according to EN27888 (DIN 38404) | |||
| display; | approx. 10mm high, 4-digit LC-display | |||
| output signal: |
4 to 20 mA (2-wire), standard 0 to 1 V or 0 to 10 V (3-wire), against upcharge |
|||
| electric isolation: |
input electrically isolated |
|||
| auxiliary energy: | 12 to 30 V DC
(for option 0 to 10 V: 18 to 30 V DC) |
|||
| reverse voltage protection: | 50 V permanent | |||
| perm. impedance: | (at 4 to 20 mA): RA[Ω] = (UV [V] - 12V) / 0.02 A | |||
| permissible load: | (at 0 to 10 V): RL > 3000 kΩ | |||
| working temperature: |
-25°C to +50°C (transducer) 0°C to +80°C (standard meas. cell) |
|||
| storage temperature: | -25°C to +70 °C | |||
| electrical connection: | elbow-type plug acc. to DIN 43650 (IP65) | |||
| housing: | ABS (IP65) with the exception of electrode socket | |||
| dimensions: | 82 x 80 x 55mm (W x D x H), without elbow-type plug and socket | |||
| mounting: | with fixing holes for wall mounting: mounting distance: 70 x 50mm (W x H) |
|||
| options (against upcharges): |
| AV: | output signal 0 to 1 V or 0 to 10 V, please notice in order |
| PG: | electrode with thread PG13.5 (for use up to 6bar) |
| KL: | longer meas. cell cable (recommended max. 5m) |
| accessories (against upcharges): |
| LFE 202: | spare 2-pol measuring cell |
| PG 13.5: | plug on thread adapter for pressure-free use |
| GKL 100: | 100ml controlling solution, 1413 µS/cm (acc. to DIN 27888) |
| GEH 1: | swivel-arm electrode retainer |