No more water damage!

 

Application:  

any devices or machines with water connection.
For direct mounting of solenoid valve in pipelines.

GEWAS181A

GEWAS 181 A                                        

leak-water detector with 1/2" (= 1,27 cm)-brass solenoid
valve with 3/4" (= 1.905 cm) connections for hand installation,
water sensor, alarm buzzer and switch-off of connected units 16 A, 230 V

GEWAS 183 A                                        

leak-water detector without solenoid valve, with
water sensor, alarm buzzer and switch-off of connected devices 16A, 230 VAC

GEWAS 181 A - 1/2" (= 1,27 cm)                        

leak-water detector with 1/2" (= 1.27 cm) brass solenoid valve
(flow quantity: approx. 20 l/min, installation length approx. 55 mm)
for installation in the line, water sensor, alarm buzzer and switch-off
of connected devices 16A, 230 VAC

GEWAS 181 A - 3/4"  (= 1,905 cm)                            

leak-water detector with 3/4" (= 1.905 cm) brass solenoid valve
(flow quantity: approx. 91.5 l/min, installation length approx. 80 mm)
for installation in the line, water sensor, alarm buzzer
and switch-off of connected devices 16A, 230 VAC

GEWAS 181 A - 1" (= 2,54 cm)                                 

leak-water detector with 1" (= 2.54 cm) brass solenoid valve
(flow quantity: approx. 141.5 l/min, installation length approx. 95 mm)
for installation in the line, water sensor, alarm buzzer and switch-off of connected devices 16A, 
230 VAC

 

Specification:

Solenoid valve:  
Brass solenoid valve, energy-saving circuitry for hand-installation
(1/2" (= 1.27 cm) with 3/4" (= 1.905 cm) glanding - suitable for any 1/2" (= 1.27 cm) tap or 1/2" (= 1.27 cm) tube)
or with 1/2" (= 1.27 cm), 3/4" (= 1.905 cm) or 1" (= 2.54 cm) internal thread on both sides for line installation. 
De-energised when closed, for pressure loads from 0.5 to 10 bar. Servo-controlled,
i.e. free  water outlet has to be provided resp. infeed pressure has to exceed
outfeed pressure by 0.5 bar (solenoid not suitable for closed circuits such as heating systems).

 

Electric specification:

of solenoid: 100 V DC, approx. 2 W.
Full load of approx. 8 watt available when start button is pressed at approx. 200 V DC. 
Hence, valve operable in permanent mode; due to energy- saving circuit valve will not run hot even without cooling agent. 
Valve permanently fixed to control device (approx. 1 m of connecting cable). 
Valve body can be removed from coil after loosening of one nut.
Water sensor: Highly sensitive, plug-in water sensor, 2 m of cable, alarm triggered as of 1/2 mm water film.
Simultaneous plug-in of several water sensors via socket-outlet adapter GAZ 1. 
Plug-in extension cable (2, 5 or 10 m long) available.
Alarm triggering: Solenoid closing in case of alarm, buzzer sounding and machine connected will turned off by means of a single-pole one-way switch.
Control device: 112 x 71 x 48 mm (H x W x D) with suspension hook.
Operating lamps, double-pole switch, start button, alarm buzzer, approx. 1 m of connecting cable with  earthing pin plug and socket.
Socket (16 A, 230 V) is alarm triggered, i.e. the device plugged-inwill be disconnected in case of alarm.
Power consumption: approx. 3 W only due to energy-saving circuit of solenoid valve.

 

Accessories (against upcharge):

Spare solenoid valves upon request!

Further accessories:

GWF 1-S plug-in water sensor
GAZ-1 socket-outlet adapter (required for each additional water sensor)
VEKA 2 extension cable 2m
VEKA 5 extension cable 5 m
VEKA 10 extension cable 10 m