conductivity measuring device
for ultra-pure water
highlights: |
|
the measuring cells: | |
|
The measuring
cells are designed without any compromise. By the openings of the sensors the electrodes are well washed around and well-protected against mechanical influences. The integrated temperature sensors response very quickly. Compared with more simple electrode types the measurements are much faster and much more precise |
||
area of application: |
A
universal applicability at highest standards is guaranteed, since the electrode material is made of stainless steel (1.4404, 1.4435). |
picture follows within short time! | |
|
GLF 100 RW
![]() |
Specifications: |
measuring ranges: | conductivity; | 0 to 2,000µS/cm |
0.00 to 20.00µS/cm | ||
0.0 to 100.0µS/cm | ||
temperature: | -5.0°C to +100.0 °C | |
resistivity: | 0.0100 to 0.2000 MΩ*cm | |
0.010 to 2,000 MΩ*cm | ||
0.01 to 20.00 MΩ*cm | ||
accuracy: | (+1 digit, at nominal temperature = 25°C) | |
conductivity: | typ. 1.5% FS | |
temperature: | +0.3°C | |
temperature compensation: | off: | deactivated |
nLF: | non-linear, acc. to EN 27888 | |
LIN: | linear, with adjustable coefficients | |
NaCl: | compensation for weak NaCl-solutions acc. to EN 60746-3 | |
reference temperatures: +20°C and +25°C | ||
measuring cell: | 2-pole-measuring cell, diameter 12mm
(stainless steel: 1.4404, 1.4435) with integrated temperature sensor |
|
display: | approx. 11mm high, 4 1/2-digit LCD-display | |
working conditions: | device: | -25°C to +50°C, 0 to 95% r.h. (non-condensing) |
measuring cell: | -5°C to +80°C (for short-time: +100°C) | |
power supply; | 9V-battery, Typ 6F22 (in scope of supply) | |
power consumption: | <1.5mA | |
housing: | impact resistant ABS, plastic foil keyboard, transparent panel, front side IP65 |
|
dimensions (device): | 110 x 67 x 30mm (H x W x D) | |
weight: | approx. 155g | |
device functions: | ||
hold function: | by pressing a key the current measuring value is "frozen" | |
min-/max-value memory: | the min. and max. measured value is stored | |
power-off-function: | device turns off after a certain time, if it is
not used (adjustable: 1-120min or deactivated) |
accessories (against upcharges): |
GKL100: | conductivity controlling solution (100ml bottles with 1.413µS/cm (acc. to DIN EN 27888)) |
GKL 101: | conductivity controlling solution (250ml bottles with 84 µS/cm) |
GEH 1: | pivot-arm electrode-holder (for up to 4 elektrodes/probes max.) |
GWZ-01: | flow-through chamber (for measuring cell with diameter of 12mm) |
ST-KR: | protection bag (for device) |
GB 9V: |
spare battery 9V/ approx. 300mAh, type 6F22 |
GKK 252: | case with punched lining (235 x 185 x 48mm) |
GKK 3100: | case with punched lining (275 x 229 x 83mm) |